Consistently use config FOO bool/int/hex/string "Prompt text" instead of config FOO bool/int/hex/string prompt "Prompt text" (...and a bunch of other variations that e.g. swapped the order of the type and the 'prompt', or put other properties between them). The shorthand is fully equivalent to using 'prompt'. It saves lines and avoids tricking people into thinking there is some semantic difference. Most of the grunt work was done by a modified version of https://unix.stackexchange.com/questions/26284/ how-can-i-use-sed-to-replace-a-multi-line-string/26290#26290, but some of the rarer variations had to be converted manually. Signed-off-by: Ulf Magnusson <Ulf.Magnusson@nordicsemi.no>
101 lines
2.4 KiB
Plaintext
101 lines
2.4 KiB
Plaintext
# Kconfig - TMP007 infrared thermopile sensor configuration options
|
|
|
|
#
|
|
# Copyright (c) 2016 Intel Corporation
|
|
#
|
|
# SPDX-License-Identifier: Apache-2.0
|
|
#
|
|
|
|
menuconfig TMP007
|
|
bool "TMP007 Infrared Thermopile Sensor"
|
|
depends on I2C
|
|
help
|
|
Enable driver for TMP007 infrared thermopile sensors.
|
|
|
|
config TMP007_NAME
|
|
string "Driver name"
|
|
default "TMP007"
|
|
depends on TMP007
|
|
help
|
|
Device name with which the TMP007 sensor is identified.
|
|
|
|
config TMP007_I2C_ADDR
|
|
hex "I2C address for TMP006 Sensor"
|
|
depends on TMP007
|
|
default "0x40"
|
|
help
|
|
I2C address of the TMP007 sensor.
|
|
|
|
0x40: A0 connected GND and A1 connected to GND.
|
|
0x41: A0 connected VDD and A1 connected to GND.
|
|
0x42: A0 connected SDA and A1 connected to GND.
|
|
0x43: A0 connected SCL and A1 connected to GND.
|
|
0x44: A0 connected GND and A1 connected to VDD.
|
|
0x45: A0 connected VDD and A1 connected to VDD.
|
|
0x46: A0 connected SDA and A1 connected to VDD.
|
|
0x47: A0 connected SCL and A1 connected to VDD.
|
|
|
|
config TMP007_I2C_MASTER_DEV_NAME
|
|
string "I2C master where TMP007 is connected"
|
|
depends on TMP007
|
|
default "I2C_0"
|
|
help
|
|
Specify the device name of the I2C master device to which the
|
|
TMP007 chip is connected.
|
|
|
|
choice
|
|
prompt "Trigger mode"
|
|
depends on TMP007
|
|
default TMP007_TRIGGER_NONE
|
|
help
|
|
Specify the type of triggering to be used by the driver.
|
|
|
|
config TMP007_TRIGGER_NONE
|
|
bool "No trigger"
|
|
|
|
config TMP007_TRIGGER_GLOBAL_THREAD
|
|
bool "Use global thread"
|
|
depends on GPIO
|
|
select TMP007_TRIGGER
|
|
|
|
config TMP007_TRIGGER_OWN_THREAD
|
|
bool "Use own thread"
|
|
depends on GPIO
|
|
select TMP007_TRIGGER
|
|
|
|
endchoice
|
|
|
|
config TMP007_TRIGGER
|
|
bool
|
|
depends on TMP007
|
|
|
|
config TMP007_GPIO_DEV_NAME
|
|
string "GPIO device"
|
|
default "GPIO_0"
|
|
depends on TMP007 && TMP007_TRIGGER
|
|
help
|
|
The device name of the GPIO device to which the TMP007 interrupt
|
|
(alert) pin is connected.
|
|
|
|
config TMP007_GPIO_PIN_NUM
|
|
int "Interrupt GPIO pin number"
|
|
default 0
|
|
depends on TMP007 && TMP007_TRIGGER
|
|
help
|
|
The number of the GPIO pin on which the interrupt signal from the
|
|
TMP007 chip will be received.
|
|
|
|
config TMP007_THREAD_PRIORITY
|
|
int "Thread priority"
|
|
depends on TMP007 && TMP007_TRIGGER_OWN_THREAD
|
|
default 10
|
|
help
|
|
Priority of thread used by the driver to handle interrupts.
|
|
|
|
config TMP007_THREAD_STACK_SIZE
|
|
int "Thread stack size"
|
|
depends on TMP007 && TMP007_TRIGGER_OWN_THREAD
|
|
default 1024
|
|
help
|
|
Stack size of thread used by the driver to handle interrupts.
|