Rename the controller Kconfig option BT_LL_SW to
BT_LL_SW_LEGACY in preparation towards switch to new Link
Layer implementation.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Introduce a separate buffer pool for events which the HCI driver
considers discardable. Examples of such events could be e.g.
Advertising Reports. The benefit of having such a pool means that the
if there is a heavy inflow of such events it will not cause the
allocation for other critical events to block and may even eliminate
deadlocks in some cases.
Also update all mesh samples not to specify explicit RX buffer counts
anymore. Instead, create appropriate defaults in Kconfig so that we
only need to override this in the app for cases like the bbc:microbit
with limited memory.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This event is a priority one, so it's not safe to have it use the RX
buffer pool which may be depleted due to non-priority events (e.g.
advertising events). Since the event is consumed synchronously it's
safe to have a single-buffer pool for it. Also introduce a new
bt_buf_get_evt() API for HCI drivers to simplify the driver-side code,
this effectively also deprecates bt_buf_get_cmd_complete() which now
has no in-tree HCI driver users anymore.
Fixes#16864
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
move misc/stack.h to debug/stack.h and
create a shim for backward-compatibility.
No functional changes to the headers.
A warning in the shim can be controlled with CONFIG_COMPAT_INCLUDES.
Related to #16539
Signed-off-by: Anas Nashif <anas.nashif@intel.com>
move misc/util.h to sys/util.h and
create a shim for backward-compatibility.
No functional changes to the headers.
A warning in the shim can be controlled with CONFIG_COMPAT_INCLUDES.
Related to #16539
Signed-off-by: Anas Nashif <anas.nashif@intel.com>
move misc/byteorder.h to sys/byteorder.h and
create a shim for backward-compatibility.
No functional changes to the headers.
A warning in the shim can be controlled with CONFIG_COMPAT_INCLUDES.
Related to #16539
Signed-off-by: Anas Nashif <anas.nashif@intel.com>
move clock_control.h to drivers/clock_control.h and
create a shim for backward-compatibility.
No functional changes to the headers.
A warning in the shim can be controlled with CONFIG_COMPAT_INCLUDES.
Related to #16539
Signed-off-by: Anas Nashif <anas.nashif@intel.com>
move atomic.h to sys/atomic.h and
create a shim for backward-compatibility.
No functional changes to the headers.
A warning in the shim can be controlled with CONFIG_COMPAT_INCLUDES.
Related to #16539
Signed-off-by: Anas Nashif <anas.nashif@intel.com>
The the footer structure and extra bytes (rssi, resolving index etc.)
were overlapping in memory, rx_ftr was moved into the header, but the
extra and footer are still being read from the same place, extra was
written to the end. So this avoided memory corruption, but reading extra
reads wrong information.
Signed-off-by: Joakim Andersson <joakim.andersson@nordicsemi.no>
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
The old footer was appended after PDU using pointer arithmetic. Now
the footer fields have been moved to the header struct, the
footer fields are now statically located in the data structure,
this is type safe and fields can be referred to by their actual
names rather than indirectly through reference to other members,
thus avoiding pointer arithmetic. Secondly, this change will pave
the way for adding other meta data in the future.
Signed-off-by: Asger Munk Nielsen <asmk@oticon.com>
Renamed function vendor_cmd_handle to vendor_cmd_handle_common for
shared vendor commands. This allows vendor to implement
vendor_cmd_handle, containing both common and specific handling.
Signed-off-by: Morten Priess <mtpr@oticon.com>
* Rename the stack local 'done' to 'evdone' so as to disambiguate from
MFIFO_DEQUEUE_PEEK(done) which is actually 'mfifo_done'.
* add comment on ull_slave_done
* add comments to addr_us_get
* add comments to HCI_CLASS
Signed-off-by: Mark Ruvald Pedersen <mped@oticon.com>
Rename reserved function names in the subsys/ subdirectory except
for static _mod_pub_set and _mod_unbind functions in bluetooth mesh
cfg_srv.c which clash with the similarly named global functions.
Signed-off-by: Patrik Flykt <patrik.flykt@intel.com>
BT_WARN() should only be used for log messages that may indicate a
problem. However, the controller HCI code was using it for messages
that were of a pure debugging/informational nature. Convert these to
BT_DBG() instead - this should hopefully also help avoid unnecessary
user questions of seemingly alarming log messages.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Use reverse order for bitfields on big-endian architectures. Treat
all PDU data as little-endian and add conversions as needed. Treat
access address as 4-byte value instead of u32_t to avoid flipping
endianness.
Signed-off-by: Wolfgang Puffitsch <wopu@oticon.com>
It's more natural to use net_buf_pull_mem() for the HCI command
parsing. Note that this also fixes a bug in hci_cmd_handle() where it
would previously check for sufficient parameter length with the
command header still included in the buffer (which it shouldn't have
been).
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Preliminary work done towards Mesh extensions on the old LL
architecture implementation.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Missing updates to old architecture implementation towards
introduction of new ULL LLL architecture.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
This commit renames the nrf5_clock_control.h and
nrf5_clock_control.c files to nrf_clock_control.h and
nrf_clock_control.c, respectively, as they are used
in nRF9160 builds, as well.
Signed-off-by: Ioannis Glaropoulos <Ioannis.Glaropoulos@nordicsemi.no>
This commit renames the CLOCK_CONTROL_NRF5 Kconfig symbol to
CLOCK_CONTROL_NRF. The change is required to aleviates confusion
when selecting the symbol in nRF9160 SOC definition.
Signed-off-by: Ioannis Glaropoulos <Ioannis.Glaropoulos@nordicsemi.no>
Preparation to introduce the Upper Link Layer (ULL) and
Lower Link Layer (LLL) split architecture.
- Move SoC dependent HAL to vendor specific folder.
- Preparation to split data structures into ULL and LLL
types.
- Added more role and state conditional compilations.
- Added some work-in-progress implementation of advertising
extensions, will be used as inspiration in the new split
architecture work.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Add support for exchanging both minimum and maximum
connection interval values in Connection Parameter Request
Procedure implementation.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
k_poll_signal was being used by both, struct and function. Besides
this being extremely error prone it is also a MISRA-C violation.
Changing the function to contain a verb, since it performs an action
and the struct will be a noun. This pattern must be formalized and
followed and across the project.
MISRA-C rules 5.7 and 5.9
Signed-off-by: Flavio Ceolin <flavio.ceolin@intel.com>
Now that log processing happens in a separate thread, the
BT_STACK_EXTRA macro is not needed (since there's no significant
overhead), and therefore the BT_STACK macros become unnecessary as
well.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
To allow the BLE stack to be used both in the real nRF platforms
and simulated ones, change the used macros in the code to the
COMPATIBLE ones.
Signed-off-by: Alberto Escolar Piedras <alpi@oticon.com>
Calling bt_recv in the Bluetooth host Tx thread by the
controller implementation caused deadlock in combined host
controller builds when HCI LE Create Connection Cancel
generated the HCI LE Connection Complete or HCI LE Enhanced
Connection Complete events.
Controller's HCI implementation has been updated to place
the generated event into Rx FIFO to avoid the deadlock.
Relates to commit a59f544fb4 ("bluetooth: controller:
Handle non-priority events correctly")
Relates to #10314.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
In order to avoid the build system complications that come from
including a timestamp, remove it by default from the version string in
HCI Vendor Extensions. Users can still include a unique identifier, be
it timestamp or not, using the CONFIG_BT_CTLR_HCI_VS_BUILD_INFO Kconfig
option.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
When running combined build on nRF5 with disabled VS command it is
possible to simply read static random address from FICR in host.
Signed-off-by: Szymon Janc <szymon.janc@codecoup.pl>
The return of memset is never checked. This patch explicitly ignore
the return to avoid MISRA-C violations.
The only directory excluded directory was ext/* since it contains
only imported code.
Signed-off-by: Flavio Ceolin <flavio.ceolin@intel.com>
Fixed the implementation to generate command status as per
Bluetooth v5.0 specification instead of the incorrect
command complete that was generated before.
Also, the unsupported features status will be generated
before the invalid parameters status.
Relates to commit 258c7ccff1 ("Bluetooth: controller: Fix
HCI LE Set PHY invalid behavior check")
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Remove include guards in internal files; it is an agreed
convention to not have include guards in internal header
files in Bluetooth subsystem.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
In certain cases the response to a command can come in the form of a
non-priority event. This is the case of LE Create Connection Cancel,
which generates a Command Complete and then an LE (Enh) Connection
Complete. Take this case (and other future ones) into account by calling
the correct Host recv function.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Upcoming Nordic ICs that share many of the peripherals and architecture
with the currently supported nRF5x ones are no longer part of the nRF5
family. In order to accomodate that, rename the SoC family from nrf5 to
nrf, so that it can contain all of the members of the wider Nordic
family.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
When using the LE Create Connection Cancel command, the controller is
supposed to return a Command Complete first and then an LE Connection
Complete Event after. Since the Link Layer does not generate an event in
this case emulate the behavior in the HCI layer instead.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Added missing HCI Supported Commands bit fields for PHY
Update feature. Also, refactored with missing conditional
compilation for other bit fields.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Cleanup the use of long radio_pdu_node_rx and
radio_pdu_node_tx variable to shorter node_rx and node_tx
names.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Fix HCI LE Set PHY command for invalid behavior testing for
invalid parameters and unsupported features.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Fix implementation to support Connection Parameter Request
Procedure initiation with and without use of Feature
Exchange Procedure being performed in a connection.
Fixes LL.TS.5.0.2 conformance tests:
LL/CON/MAS/BV-81-C [Initiating Connection Parameter Request
- Unsupported Without Feature Exchange]
LL/CON/MAS/BV-82-C [Initiating Connection Parameter Request
- Unsupported With Feature Exchange]
LL/CON/SLA/BV-85-C [Initiating Connection Parameter Request
- Unsupported Without Feature Exchange]
LL/CON/SLA/BV-86-C [Initiating Connection Parameter Request
- Unsupported With Feature Exchange]
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Fixed implementation to disallow setting Bluetooth device
address under active advertising or scanning states.
Fixes LL.TS.5.0.2 conformance tests:
LL/CON/INI/BV-01-C [Connection Initiation]
LL/SEC/ADV/BV-01-C [Advertising With Static Address]
LL/SEC/SCN/BV-01-C [Random Address Scanning]
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Rename some legacy upstream and downstream interfaces in
radio_* namespace to ll_* namespace for consistency.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Refactor Kconfig and CMakelists.txt to be able to
conditionally compile in BT_LL_SW variant in the controller
subsystem. This is done to support future controller with
vendor specific variant implementations.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
The main purpose of recv_thread is to process incoming events from the
radio and also any buffered items waiting to be dispatched to the Host
and that are pending because of lack of Host buffers.
When an iteration of the recv_thread obtains a element from the radio it
needs to process it immediately, either sending it straight away to the
Host or appending it to the queue. This was not the case before this
patch, where the concurrency of a buffered packet with one coming from
the radio would cause the latter to be "dropped", causing missing
packets.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
When a connection is disconnected with outstanding unacked packets, the
Host has no way to signal or acknowledge their processing to the
Controller, since it is illegal to send a Host Number of Completed
Packets command when the connection is not up. Instead, consider the
outstanding packets as acked in order not to affect the correct flow
control.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Since the Zephyr HCI VS extensions apply to both the Host (using them
for additional functionality) and the Controller (implement the commands
and events), it make sense to make this a common setting in order for it
to be configurable in a way that applies to both.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Implement the Read Build Information VS command. This returns a UTF-8
encoded string, which is extendable by the user via a new Kconfig
option.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Implement the Zephyr VS command that allows a Host to write a public
Bluetooth Address to the Controller in order to allow Hosts to provide
their own public Bluetooth addresses.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
The status in the Command Complete event was uninitialized, leading to
incorrect contents of the event parsed by the Host. Correctly initialize
the status to success.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Whenever the HCI ACL flow control is violated by the Host, a Data Buffer
Overflow event is now issued by the Controller (if enabled) to notify
the Host of the buffer overrun.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Use the macros generated during the build and located in version.h to
fill in the version information in the Read Version Information VS
command. Additionally reply with the correct hardware identifiers when
running on Nordic hardware.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Implement the Zephyr Read Key Hierarchy Roots command, returning the IR
and ER present in nRF5x ICs when compiling for those.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Implement the first Vendor-Specific Command of the Zephyr specification
other than the 3 mandatory ones already present in the codebase, along
with a Kconfig option to enable and disable the presence of the VS
commands.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
This is necessary in order for k_queue_get to work properly since that
is used with buffer pools which might be used by multiple threads asking
for buffers.
Jira: ZEP-2553
Signed-off-by: Luiz Augusto von Dentz <luiz.von.dentz@intel.com>
Refactor the Connection Parameter Request Procedure to be
separate from and not overlap the variables of the
Connection Update Procedure.
Also, added missing implementations to pass all Connection
Parameter Request Procedure related Conformance Tests.
Jira: ZEP-1918
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Implement the LE Read Channel Map HCI command, along with making the
reading of the multi-byte channel map value from the connection pointer
thread-safe in case the ISR triggers while we are reading the value.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Although the current BLE controller only supports a single TX power (0
dBm), the qualification tests require the 2 Read TX Power to be
present and supported in the controller, so implement them while
returning always 0 dBm.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
When the CONFIG_BT_CTLR_CONN_RSSI option is set, the connection RSSI is
available in the controller, and can be reported to the Host via the
Read RSSI command. Implement the command, which is required for
qualification.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
There are 2 possible interpretations regarding the address to return in
response to the Read Peer RPA HCI Command:
1) The RPA that the local controller generates to be used in certain
packets it sends
2) The RPA generated and used by the peer device in its packets
We used to return 1) but our interpretation turned out to be incorrect
when reading the HCI test specification, so this commit switches to
returning 2).
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
The Read Remote Version Information command is supported on the BLE
controller, enable the bit in Read Local Supported Commands to reflect
this.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
The RSSI value is an 8-bit signed integer. Since the Link Layer works
only with positive unsigned integers, translate into a negative number
at the HCI layer.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Since Extended Scanner Filter Policies is an independent feature from
Controller-based Privacy, split it out so it can be built independently
and included without it.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Rename the BT_CONTROLLER prefix used in all of the Kconfig variables
related to the Bluetooth controller to BT_CTLR.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Implement the 4.2 event LE Directed Advertising Report, used for
scanners in a privacy-enabled controller to report directed advertising
events whose TargetA cannot be resolved by the local controller.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Add implementation to support PHY update procedure with
packet transmit time restrictions.
This fixes:
TP/CON/SLA/BV-49-C [Initiating PHY Update Procedure Packet
Time Restrictions]
TP/CON/SLA/BV-50-C [Responding to PHY Update Procedure
Packet Time Restrictions]
TP/CON/SLA/BV-52-C [Initiating PHY Update Procedure Packet
Time Restrictions, No Change]
TP/CON/SLA/BV-53-C [Responding to PHY Update Procedure
Packet Time Restrictions, No Change]
TP/CON/MAS/BV-49-C [Initiating PHY Update Procedure Packet
Time Restrictions]
TP/CON/MAS/BV-50-C [Responding to PHY Update Procedure
Packet Time Restrictions]
conformance tests in LL.TS.5.0.0.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
The API name space for Bluetooth is bt_* and BT_* so it makes sense to
align the Kconfig name space with this. The additional benefit is that
this also makes the names shorter. It is also in line with what Linux
uses for Bluetooth Kconfig entries.
Some Bluetooth-related Networking Kconfig defines are renamed as well
in order to be consistent, such as NET_L2_BLUETOOTH.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Advertising reports generated by a scanner require the controller to
look up the resolving list to supply the host with an ID address instead
of the RPA that has been sent over the air.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Implement the LE Enhanced Connection Complete HCI event, but include it
only when controller-based privacy is enabled, since it is only relevant
with it.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Since a connection attempt can fail and will still generate an LE
Connection Complete event, check the status from the LL control module
before incrementing the HCI connection count used for flow control.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Added BUILD_ASSERT check for Tx and Rx thread priorities.
The Tx thread priority shall be higher than Rx thread
priority in order to correctly detect transaction violations
in ATT and SMP protocols. The Number of Completed Packets
for a connection shall be processed before any new data is
received and processed for that connection.
The Controller's priority receive thread priority shall be
higher than the Host's Tx and the Controller's Rx thread
priority.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
The following error and warning is received when connecting
to certain central devices:
[bt] [ERR] hci_num_completed_packets: packets count mismatch
[bt] [WRN] bt_att_recv: Ignoring unexpected request
This could happen if Tx-ed packet is not added to pending
list before a num of completed packets event and/or new Rx
packet is received.
This is fixed by reducing the Rx thread priorities in the
Host and the Controller.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
The HCI Read Remote Version Information Complete event structure was
incorrect, leading to qualification test failures. This patch fixes the
structure and also the storing of the data in an endianness-agnostic
manner.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Correct the default value (0x0) for the Event Mask Page 2 and add the
command to set it to the list of supported commands.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Correctly filter out the Authenticated Payload Timeout Expired event
based on the bit present on page 2 of the Event Mask.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
In order to be able to filter events present in Page 2 of the Event
Mask, this command allows the Host to set the Page 2 of the bitmask
through the corresponding command.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Add handling of the LE Set Privacy Mode HCI Command along with the logic
required to take it into account when populating the hardware filters.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Properly use the role and feature Kconfig variables to populate both the
supported commands and the supported states in the controller.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
For whitelist and resolving list handling, avoid trying to start the
advertiser and scanner roles when they are already running.
Additionally, and since simultaneous scanning and initiating is not
supported, correctly report this to the host both in the supported
states and in the HCI command via an error code, instead of silently
disabling scanning.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
An OCF is a 10-bit value as defined by HCI, and therefore requires a
16-bit integer to store it.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
This initial commit adds the following:
* Handling of privacy HCI commands
* New Link Layer filter module for both whitelist and resolving list
* Advertising RPA generation with timeouts
Follow-up commits will expand the functionality.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Use globally available find_lsb_set in Zephyr instead of a
custom find first set function.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
In order to reuse code, the reset() function is used both to handle the
reset HCI command but also to initialize the internal HCI variables when
bringing up the system. In the latter case, avoid setting the reset bit
in the state atomic and signalling the polling API, since that is not
required during initialization.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
As a preparation for advanced filtering (Controller-based privacy) this
commit refactors whitelisting so that it becomes its own module and
actually correctly performs state tracking to avoid modifying the
whitelist when it's in use.
Additionally it also removes the duplicate separate entries for
advertising and scanning, since the specification only allows one single
global whitelist singleton.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Under invalid host behavior, trying to start advertising
while already active would corrupt the advertiser context.
This is fixed by having an explicit flag to check whether
advertiser is already running.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Under invalid host behavior, trying to start scanning while
already active would corrupt the scanner context. This is
fixed by having an explicit flag to check whether scanner is
already running.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Add Kconfig option to be able to conditional compile the
Bluetooth v4.0 LE Encryption procedure.
This is needed in order to be able to not support encryption
on nRF51 series when using Data Length Update procedure with
upto 251 byte payloads until a software-based CCM support is
implemented.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Since role support is fundamental to both the Host and the Controller,
move the role configuration options to the top-level file and rename
them to fit the GAP specification, avoiding confusion between GAP and LL
names.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Return error codes for HCI Tx buffer overflow conditions are
missing which would lead to silent dropping of Tx packets if
host implementations do not follow number of completed packets
or use correct buffer counts as returned by HCI Read Buffer
Size command.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Since more and more code is going to be reused by both the Host and the
Controller, this commit introduces a common/ folder that will contain
everything that is not tied to one of the two components but shared by
them.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
When Controller to Host flow control is enabled, output informational
messages for certain operations to help tune and debug the feature.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Added support for Bluetooth v5.0 PHY Update Procedure in the
Controller.
Asymmetric PHY connections do not work for now due to the
Radio mode not being setup in time in the ISR during tIFS
period and the Radio already ramping up in the cached
previous Radio mode to meet tIFS deadline.
Subsequent commits will add this feature, by either double
buffering the mode in software or using fast radio ramp up
which gives enough time in the ISR to change the mode.
Jira: ZEP-2086
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Implement the framework for LE Scan Request Received Event.
The feature is available under the Controller's advanced
features and will be selected implcitly when Bluetooth v5.0
LE Advertising Extensions feature is implemented.
Jira: ZEP-2073
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Remove unreferenced function hci_evt_is_discardable after
introduction of hci_get_class function.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
To guarantee code that is endianness-independent, the sys_le* macros
must be used everywhere when accessing multi-byte values from the
command parameters.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
In HCI, the response buffer to a command is the same as the one for the
command itself, requiring command parameters to be processed before the
response is formed on the same memory area.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Since Controller to Host flow control is a feature that affects both
sides equally, move it to the top-level Kconfig file and consolidate its
use in both Controller and Host.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Enable the bits corresponding to the new 3 commands supported when
enabling Controller to Host Flow Control, in order for the Host to be
able to enable the feature.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
The Bluetooth Specification allows for optional Controller to Host flow
control based on the same credit-based mechanism as the Host to
Controller one. This is particularly useful in 2-chip solutions where
the Host and the Controller are connected via a physical link (UART, SPI
or similar) where the Host is sometimes required to ask the Controller
to throttle its data traffic while still making sure that relevant
events get through the line.
This implementation is based on a simple queue of pending events and
data that is populated whenever the Controller detects that the Host is
out of buffers and then emptied whenever the Host notifies the
Controller that is ready to receive data again. Events relevant to the
connections are also queued to preserve the order of arrival.
At this point the Controller ignores the connection handle sent by the
Host and treats all connections equally, and it also queues events even
for connections that have no data pending in the queue. Both this items
can be improved if necessity arises.
Note that Number of Completed Packets will still flow freely from the
Controller to the Host regardless of the pending ACL data packets, which
might lead to inconsistencies in the sequential order of certain
operations that include bi-directional data transfer.
Jira: ZEP-1735
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Rename ll_address_* to ll_addr_*. Also, update ll_addr_get
to return reference to stored public or random address.
Change-id: I22cb0135d2223f679c4d9321f4724f8b7de0aede
Signed-off-by: Vinayak Chettimada <vinayak.kariappa.chettimada@nordicsemi.no>
Rename occurences of bt_hci_ev_* to more widely used
bt_hci_evt_* namespace.
Change-id: I742fb86f8f835a0f6072638e1e997ad08891d43d
Signed-off-by: Vinayak Chettimada <vinayak.kariappa.chettimada@nordicsemi.no>
The switch from C99 integer types to u16_t, etc. caused misalignment
in structs and function definitions with multi-line parameter lists.
Change-Id: I1448b159ab1afe50ff88b7a6bd1b254c44858d4c
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Convert code to use u{8,16,32,64}_t and s{8,16,32,64}_t instead of C99
integer types.
Jira: ZEP-2051
Change-Id: I8f57a17f78e674aca5400f005db8975c9f9e150e
Signed-off-by: Kumar Gala <kumar.gala@linaro.org>
This is a start to move away from the C99 {u}int{8,16,32,64}_t types to
Zephyr defined u{8,16,32,64}_t and s{8,16,32,64}_t. This allows Zephyr
to define the sized types in a consistent manor across all the
architectures we support and not conflict with what various compilers
and libc might do with regards to the C99 types.
We introduce <zephyr/types.h> as part of this and have it include
<stdint.h> for now until we transition all the code away from the C99
types.
We go with u{8,16,32,64}_t and s{8,16,32,64}_t as there are some
existing variables defined u8 & u16 as well as to be consistent with
Zephyr naming conventions.
Jira: ZEP-2051
Change-Id: I451fed0623b029d65866622e478225dfab2c0ca8
Signed-off-by: Kumar Gala <kumar.gala@linaro.org>
Added support in the Controller for increased feature set
bit fields in Bluetooth 5.0. Cached feature set in the
connection context is increased to a uint32_t value to
accommodate 17 feature bits.
Change-id: I9ae15d6d90fa7a3de186905d3c68088ee22d2911
Signed-off-by: Vinayak Chettimada <vinayak.kariappa.chettimada@nordicsemi.no>
To avoid having to define a BIT64() macro in a public namespace, use
instead masks directly instead of bits, and also refactor the host code
so that it uses those instead of the earlier byte array with hardcoded
indices and masks.
Change-id: Ief03db616a96df65349d24289b62566a268ffdd0
Signed-off-by: Vinayak Chettimada <vinayak.kariappa.chettimada@nordicsemi.no>
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
For consistency, "chan" and "param" are used wherever "channel" and
"parameters" are the words in the specification.
Change-Id: I778a8501ae6af991618c14cc6e395d765a9ae102
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Conditionally declare the iterator variable to avoid a warning when
compiling the controller without any duplicate filter entries.
Change-Id: I69e23d4c594db18172dc57d45e7925243fe2da69
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
HCI event masking allows the host to choose which events are reported to
it to avoid interruption and excessive traffic. This patch implements
masking to drop any non-enabled events as specified by the host.
Jira: ZEP-1769
Change-Id: If09d4aa22b0da8f743fc42a3b0db3f369daaff96
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Implement the controller's ability to drop duplicate advertising reports
when instructed by the Host.
Jira: ZEP-1246
Change-Id: I2d1b7abf1ed950dde705e5df30a858c595f3834c
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
In case the controller is receiving PDUs very rapidly, prevent it from
spamming the logs by limiting its stack analysis to at most once every
5 seconds.
Change-Id: I31c70d28e8af62b27172a4a77bf6e614ea3e20eb
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Cleanup controller's root makefile and add folder level
makefile to have better control over dependencies.
Also explicitly include folder paths in c files to clearly
depict the dependencies.
Change-id: Iac7b3a86eff11082111049ba48559c74f6c4d3fb
Signed-off-by: Vinayak Chettimada <vinayak.kariappa.chettimada@nordicsemi.no>
Updated controller code to use NULL keyword instead of
using 0 for pointers.
Change-id: I5ebff53dfeeba670fb7afe4740596b2662eb0334
Signed-off-by: Vinayak Chettimada <vinayak.kariappa.chettimada@nordicsemi.no>
The current hci_driver.c contained all the software Link Layer
initialization code. To decouple HCI from the actual LL, most of the
functionality that is actually part of the LL has been moved to the
ll_sw folder, opening the possibility for future hardware-based LL
implementations.
Change-Id: I1b54d655568a4ec02409da2f1a0addb4d64beed0
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Since this presents a risk of public Bluetooth address duplication in
the wild by compiling once with a particular address and then flashing
the same image to multiple devices, a decision has been taken to remove
that config option and replace it later with another mechanism.
Change-Id: I068db25b2996c2409630554b1819b6adc48226cd
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
To present a common interface to both software and hardware Link Layers
the API in ll.h now lives in its own separate include/ folder.
Change-Id: I2b0ab0d11b47b9c35a5759bcc30f347e6c616648
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Declaring these as const lets the linker generate more optimal code.
Some extra care is needed with hci_ecc.c since it was overwriting the
send callback. Now the choice of send() call is done directly in the
bt_send() function
Change-Id: Iac74f5ee9bee097bbb34c11bd13d1d886700f5cc
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Rename all LL downstream API calls from radio_ to ll_ so that they
reflect the layer they are actually targeting. Additionally they have
been moved to ll.h so as to expose a proper interface.
Change-Id: I4fb3946597920c9fafaacb6d87d34d83d75e8f27
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>